Product Name: SS-5000 Multi-channel Synchronous Sampling Gas Flux Monitoring System
上市Date:2026-03-31

This system uses patented technology to achieve automated synchronous collection of greenhouse gases in soil across multiple channels. After collection, the concentration and flux of greenhouse gases in each channel are accurately measured channel by channel.

This system uses patented technology to achieve automated synchronous collection of greenhouse gases in soil across multiple channels. After collection, the concentration and flux of greenhouse gases in each channel are accurately measured channel by channel.

Main Features

• The system measures soil greenhouse flux at multiple locations for continuous, unattended, and long-term monitoring, up to 48 open-top flux chambers 

• Optional soil emission measurement for N2O, CH4 , CO2 , NH3 , OCS, CO2 isotope, N2O isotope, and others, connected to different NDIR and laser gas analyzers from different manufacturers 

• During measurement, open-Top Chambers are automatically closed, then the control system can simultaneously collect gas samples from all chambers, measure changes in gas concentration in the airbags over a set period, and calculate the flux value 

• This patent technology enables real synchronous measurement of greenhouse gas fluxes across multiple field plots

Specifications

Greenhouse gas analyzer 

simultaneously measure 5 greenhouse gases 

Accuracy (1δ,1 sec / 10 sec) :

CO2:< 0.5 ppm / < 0.15ppm

CH4:< 4 ppb  / < 1.2 ppb

N2O:< 500 ppt (1s)

CO:< 500 ppt (1s)

H2O:< 100 ppm (1s)

Measurement range:

CO2:0-10000ppm

CH4:1-100ppm

N2O:2 ppb - 500 ppm

CO:1 ppb - 500 ppm

H2O:0-3%

Open Top Chamber

External Dimensions:Height ≥ 1.2 m

Measuring Area:≥ 0 . 64 m² ( open - top combined structure)

Motion Performance:Electric actuator drive

Opening/Closing Time:≤ 20 s

Power:< 5 W

Environmental Conditions:Operating temperature -20℃ to 60℃, built-in 4 fans for forced mixing


In-situ synchronous sampling system in the field

Number of channels:9-48 (Independent solenoid valve, independent air pump)

Control method:Programmed control of rinsing, opening and closing, and synchronous gas intake (parameters can be set independently)

Gas circuit protection:The assimilation chamber is equipped with a gas flushing and rinsing function and has an automatic airtightness check function

Protection level:Solenoid valve pressure resistance ≥6.9 bar; interface IP68; core control box IP65; cable plug-in self-locking



Related cases / Case More>>
Copyright ©2018-2023 LICA United Technology Limited
犀牛云提供企业云服务

LICA United Technology Limited

Address:The 5th.Building,No.18,Anningzhuang East Road,Haidian District, 100085, Beijing, China.

Tel:010-51292601
Fax:010-82899770-8014
E-mail:info@li-ca.com

 


 

 


 
  • Name:
  • *
  • 公司名称:
  • *
  • 地址:
  • *
  • 电话:
  • *
  • 传真:
  • *
  • E-mail:
  • *
  • 邮政编码:
  • *
  • 留言主题:
  • *
  • Details:
  • *
Feedback
Follow us
  • Wechat
  • Mobile Website
友情链接: